2000インバータ付き 24v から 110v 120v 220v 230v 240v インバータ dc から ac 2000 ワット 24v インバータ
当社を選ぶ理由
- 低価格
- 安定したパフォーマンス
- 安全性, 信頼性
- 長寿命
説明
2000w inverter 24v to 110v 120v 220v 230v 240v inverter dc to ac 2000w 24v inverter
Carutu 2000Watt Pure Sine Wave Power Inverter 12V 24V 48V DC to 110V 220V AC with LCD Display True rated continuous 2000Watts pure sine wave output power and 4000Watts peak power, 特集 1 ユニバーサルACソケット, 1 インテリジェント冷却ファンと 1 LCD display.It is widely applications for indoor and outdoor uses-Ideal for RVs,Boats,and powerfailure emergencies with this 2000W heavy duty inverter.Featured with a Intelligent multifunction LCD display,which not only canlet users know AC/DC voltage, 力 ,temperature etc, but also know failure cause.
モデル:CRD-2000WOutput Waveform:pure sine waveRated Power: 2000WPeak Power: 4000WOutput voltage: AC100/110/120/220/230/240Input voltage:DC12/24/48/60/90/110Frequency:60HZ/50HZSize:350*153*70mm N.W.:3.0KGS
モデル
|
CRD-2000W-12V
|
CRD-2000W-24V
|
CRD-2000W-48V-L
|
||
出力
|
AC voltage
|
100/110/120VAC
|
|||
Rated power
|
2000W
|
||||
Surge power
|
4000W(for few seconds)
|
||||
Waveform
|
純粋な正弦波(THD<3%)
|
||||
頻度
|
50/60Hz±3Hz
|
||||
入力
|
DC voltage
|
12V
|
24V
|
48V
|
|
電圧範囲
|
10~15VDC
|
20~30VDC
|
40~60VDC
|
||
効率
|
>87.0%
|
>90.0%
|
>90.0%
|
||
保護
|
Bat.low voltage alarm
|
11±0.5VDC
|
22±1VDC
|
44±2VDC
|
|
Bat.low voltage shut down
|
10±0.5VDC
|
20±1VDC
|
40±2VDC
|
||
Overload
|
Shutdown,then start automatically.
|
||||
Over voltage
|
15±0.5VDC
|
30±1VDC
|
60±2VDC
|
||
Over temparature
|
Shut-off output voltage, recover automatically after temperature goes down
|
||||
Short circuit
|
Shut-off output voltage, restart to recover
|
||||
Bat.reverse polarity
|
when the inverter is connected reversely, inverter’s fuse will be burnt to protect the inverter. The DC input side with protectionwill not work. You have to replace all burnt fuses.
|
||||
*60V/72V/96V/110V—-These specifications can also be customized. These data are from our laboratory.
|
Features:
Provides 6 kinds of intelligent protection which can protect your electrical equipment considerately.
1. Over Load Protection:
When connected load exceeds the inverter rated power watts (W), the inverter will automatically shut down to stop the output.
2. Over Heat Protection:
As the internal temperature of the inverter or the ambient temperature is too high, the inverter output will automatically stop to ensure the safety of electrical equipment.
3. High-Voltage Protection:
When the DC input voltage exceeds the normal range of the inverter will automatically shut down to stop the output voltage is too high note when there may be damage to the machine.
4. Low-Voltage Protection:
When the battery or power supply voltage is too low, the inverter will stop output automatic shutdown protection to protect the battery or power supply is not compromised.
5. Reverse Protection:
When the inverter link reverse to battery, inverter fuse will be blown, without damaging the product itself, you need to replace the fuse.(A reverse protection circuit no burning fuse for 300w, 500w)
6. Short Circuit Protection:
When the load is connected severe short-circuit fault, the inverter will automatically shut down to stop the output
1. Over Load Protection:
When connected load exceeds the inverter rated power watts (W), the inverter will automatically shut down to stop the output.
2. Over Heat Protection:
As the internal temperature of the inverter or the ambient temperature is too high, the inverter output will automatically stop to ensure the safety of electrical equipment.
3. High-Voltage Protection:
When the DC input voltage exceeds the normal range of the inverter will automatically shut down to stop the output voltage is too high note when there may be damage to the machine.
4. Low-Voltage Protection:
When the battery or power supply voltage is too low, the inverter will stop output automatic shutdown protection to protect the battery or power supply is not compromised.
5. Reverse Protection:
When the inverter link reverse to battery, inverter fuse will be blown, without damaging the product itself, you need to replace the fuse.(A reverse protection circuit no burning fuse for 300w, 500w)
6. Short Circuit Protection:
When the load is connected severe short-circuit fault, the inverter will automatically shut down to stop the output
レビュー