Car Power Inverter 300 watt Power Inverter DC 12V 24V to AC 110v 220v 230v with 6 protections
当社を選ぶ理由
- 低価格
- 安定したパフォーマンス
- 安全性, 信頼性
- 長寿命
説明
Car Power Inverter 300 watt Power Inverter DC 12V 24V to AC 110v 220v 230v Off Grid
モデル: CRD-300W
Output Waveform: pure sine wave
定格出力: 300W
Peak Power: 600W
Output voltage: AC100/110/120/220/230/240
入力電圧:DC12/24/48/60/90/110
頻度:60HZ/50HZ
サイズ:211*104*70んん
N.W. :0.65KGS
car power inverter Model
|
CRD-300W-12V
|
CRD-300W-24V
|
CRD-300W-48V
|
||
出力
|
AC voltage
|
100/110/120/220/230/240VAC
|
|||
Rated power
|
300W
|
||||
Surge power
|
600W(for few seconds)
|
||||
Waveform
|
純粋な正弦波(THD<3%)
|
||||
頻度
|
50/60Hz±3Hz
|
||||
入力
|
DC voltage
|
12V
|
24V
|
48V
|
|
電圧範囲
|
10~15VDC
|
20~30VDC
|
40~60VDC
|
||
効率
|
>87.0%
|
>90.0%
|
>90.0%
|
||
保護
|
Bat. low voltage alarm
|
11±0.5VDC
|
22±1VDC
|
44±2VDC
|
|
Bat. low voltage shut down
|
10±0.5VDC
|
20±1VDC
|
40±2VDC
|
||
Overload
|
Shut down, then start automatically.
|
||||
Overvoltage
|
15±0.5VDC
|
30±1VDC
|
60±2VDC
|
||
過熱
|
The shut-off output voltage recovers automatically after the temperature goes down
|
||||
Short circuit
|
Shut off output voltage, and restart to recover
|
||||
Bat. reverse polarity
|
Reverse protection circuit: A reverse protection circuit with no burning fuse
|
||||
*60V/72V/96V/110V—-These specifications can also be customized. *These data are from our laboratory.
|
Provides six kinds of intelligent protection that can protect your electrical equipment considerately.
1. Over Load Protection:
When the connected load exceeds the inverter-rated power watts (W), the inverter will automatically shut down to stop the output.
2. Over Heat Protection:
As the internal temperature of the inverter or the ambient temperature is too high, the inverter output will automatically stop to ensure the safety of electrical equipment.
3. High-Voltage Protection:
When the DC input voltage exceeds the normal range, the inverter will automatically shut down to stop the output voltage is too high, noting when there may be damage to the machine.
4. Low-Voltage Protection:
When the battery or power supply voltage is too low, the inverter will stop output automatic shutdown protection to protect the battery or power supply is not compromised.
5. Reverse Protection:
When the inverter link is reversed to the battery, the inverter fuse will be blown; without damaging the product, you need to replace the fuse. (A reverse protection circuit with no burning fuse for 300w, 500w)
6. Short Circuit Protection:
When the load is connected severe short-circuit fault, the inverter will automatically shut down to stop the output.
レビュー